Double Jacket ADSS Cable Gel-Filled

Waveoptics® Double Jacket ADSS Cable is designed for self-supporting and duct applications for cable spans up to 1,050 feet, allowing an easy and cost-effective one-step installation using standard hardware and installation methods. Reduced weight design and smaller diameter allows the usage of smaller ducts.

APPLICATIONS
PROTECTIONS

Clear

Description

Double Jacket ADSS Cable
Waveoptics® Double Jacket ADSS Cable is designed for self-supporting and duct applications for cable spans up to 1,050 feet, allowing an easy and cost-effective one-step installation using standard hardware and installation methods. Reduced weight design and smaller diameter allows the usage of smaller ducts.

Loose tubes are made of PBT which provide great mechanical properties under a wide range of conditions such as crush test and impact test, and are filled with water blocking gel.

PE double jacket with additives makes a resistant, durable and easy to strip cable, providing superior protection against UV radiation, fungus, abrasion and other environmental factors.

The SZ-stranded method for loose tubes and four ripcords ensure a quick and easy mid-span access.

Dielectric central strength member requires no bonding or grounding.

Aramid yarns have an excellent performance against high tension for direct-aerial installations, aerial to duct transitions and can be used for other applications that require added tensile performance such as long duct pulls. No messenger cable is required for installation, and no metallic components are used in ADSS cables.

Additional information

Fiber Count

2 Fibers, 4 Fibers, 6 Fibers, 8 Fibers, 12 Fibers, 24 Fibers, 36 Fibers, 48 Fibers, 60 Fibers, 72 Fibers, 96 Fibers, 144 Fibers, 192 Fibers, 216 Fibers, 288 Fibers, 432 Fibers

Fiber Type

Waveoptics G652.D, Waveoptics G657.A1, Waveoptics G657.A2, OFS G652.D, OFS AllWave® FLEX

SPAN

300 ft, 450 ft, 600 ft, 750 ft, 900 ft, 1,050 ft, 1,200 ft, 1,350 ft, 1,500 ft

NESC

Light, Medium, Heavy

Design Properties

Fiber per Tube 2-12
Dielectric Strength Member FRP
Outer Jacket Material / Thickness Polyethylene / 1.55 mm (0.06 in)
Inner Jacket Material / Thickness Polyethylene / 0.8 mm (0.03 in)
Loose Tube Diameter 2.2 mm (0.09 in)
Drum Length 10,000 ft, 15,000 ft & 20,000 ft (±5%)

Temperature Range

Operation -40°C to 70°C (-40°F to 158°F)
Installation -30°C to 70°C (-22°F to 158°F)
Storage / Transport -40°C to 70°C (-40°F to 158°F)

Mechanical Properties

Crush Resistance (Short-Term / Long-Term) 3,000 N/100mm / 1,500 N/100mm
Minimum Bend Radius (Operation / Installation) 10 x OD / 20 x OD