Single Jacket ADSS Track-Resistant Cable Gel-Filled
- Description
- Additional information
- Properties
- Data Sheets
Description
Single Jacket ADSS Track-Resistant Cable Gel-Filled
Waveoptics® Single Jacket ADSS Track-Resitant Cable is designed for self-supporting and duct applications for cable spans up to 1,050 feet, allowing an easy and cost-effective one-step installation using standard hardware and installation methods. Reduced weight design and smaller diameter allows a higher density of fiber using existing pole hardware.
Loose tubes are made of PBT which provide great mechanical properties under a wide range of conditions such as crush test and impact test, and are filled with water blocking gel.
Track-resistant PE (TRPE) single jacket with additives makes a resistant, durable and easy to strip cable, providing superior protection against UV radiation, fungus, abrasion and other environmental factors. Available for high voltage transmission lines for the following electric field potential ranges: 12 kV to 25 kV and higher than 25 kV up to 400 kV.
The SZ-stranded method for loose tubes and two ripcords ensure a quick and easy mid-span access.
Dielectric central strength member requires no bonding or grounding.
Aramid yarns have an excellent performance against high tension for direct-aerial installations, aerial to duct transitions. No messenger cable is required for installation, and no metallic components are used in ADSS cables. These attributes allow the cable to be installed live-line and in the power space of distribution lines.
Additional information
Fiber Count | 2 Fibers, 4 Fibers, 6 Fibers, 8 Fibers, 12 Fibers, 24 Fibers, 36 Fibers, 48 Fibers, 60 Fibers, 72 Fibers, 96 Fibers, 144 Fibers, 192 Fibers, 216 Fibers, 288 Fibers, 432 Fibers |
---|---|
Fiber Type | Waveoptics G652.D, Waveoptics G657.A1, Waveoptics G657.A2, OFS G652.D, OFS AllWave® FLEX |
Electric Field Potential | 12 kV to 25 kV, Above 25 kV and up to 400 kV |
SPAN | 300 ft, 450 ft, 600 ft, 750 ft, 900 ft, 1,050 ft |
NESC | Light, Medium, Heavy |
Design Properties
Fiber per Tube | 2-12 |
Dielectric Strength Member | FRP |
Outer Jacket Material / Thickness | Track-Resistant Polyethylene / 1.55 mm (0.06 in) |
Loose Tube Diameter | 2.2 mm (0.09 in) |
Drum Length | 10,000 ft 15,000 ft & 20,000 ft (±5%) |
Temperature Range
Operation | -40°C to 70°C (-40°F to 158°F) |
Installation | -30°C to 70°C (-22°F to 158°F) |
Storage / Transport | -40°C to 70°C (-40°F to 158°F) |
Mechanical Properties
Crush Resistance (Short-Term / Long-Term) | 2,200 N/100mm / 1,100 N/100mm |
Minimum Bend Radius (Operation / Installation) | 10 x OD / 20 x OD |